GENERAL SPECIFICATIONS:
Display:?? 3-3/4 digits LCD with 25mm high
numerical displays.
Auto Functions:??? Auto-zero, Auto-polarity, Auto-ranging.
Auto Power Off:??? The meter will enter into Power Off mode 30 minutes after no activity detected. When button is pushed or selector switch is turned, Power turns ON again.
??????
Low Battery Indication: " ".
?
Over range Indication: "OL".
?
Power Supply:??? Single 9V battery (NEDA 1604or IEC 6F22)
?
Reading Rate Time:?? 3 reading per sec (approx.).
?
Max. Common Mode Voltage: 500VDC or AC peak.
?
Safety Standards:?? The meter is up to the standards of IEC1010 Double Insulation, Pollution degree 2 over voltage Category .
Operating Environment: 0 ~ 50 (32~122) at ≤70% relative humidity.
Storage Environment:? -20~60 (-4~140) at ≤80% relative humidity.
Temperature Coefficient: 0.1×(specified accuracy)/(≤18 or≥28)
Accessories:?? One pair test leads, single 9V battery (NEDA 1604or IEC 6F22), operating instructions.
Fuse:????? 0.5A/250V, 5×20mm fast acting 10A/250V, 5×20mm or 5×25mm, fast acting.
Dimension:??? 155mm×97mm×50mm
Weight:?? Approx. 320g (including battery and holster).
?
ELECTRICAL SPECIFICATIONS:
*Accuracy is given as ± ([% of reading] + [number of decimal digits]) at 18~28闁硅櫣鐓?(65~83闁硅櫣鐓?, with relative humidity up to 70%.
?
DUTY CYCLE %
Ranges: 0.0~90.0%
Resolution:????? 0.1%
Pulse width:??? > 100us, <100ms
Accuracy:?????? ± (2.5%rdg+10dgt)
Overload protection: 250VDC or RMS AC
?
?
DC VOLTAGE (Auto Ranging)
Ranges: 400mV
Accuracy:????? ± (0.8%rdg+10dgt)
Ranges: 4V, 40V, 400V, 1000V
Accuracy:????? ± (0.5%rdg+5dgt)
Resolution:???? 100uV
Input impedance:??? >10MΩ
Overload protection: 1000VDC or 750VAC RMS.
?
AC VOLTAGE (Auto Ranging)
Ranges: 400mV, 4V, 40V, 400V, 750V, (400mV only in manual)
Resolution:???? 100uV
Accuracy:????? 400mV, 750V ± (1.8%rdg+10dgt) at 50~100Hz
4V, 40V, 400V, ± (1.5%rdg+10dgt) at 50~ 400Hz
Input impedance:??? >10MΩ
Overload protection: 1000VDC or 750VAC RMS.
?
DC CURRENT (Auto Ranging)
Ranges: 400uA, 4000uA, 40mA, 400mA, 10A.
Resolution:????? 0.1uA
Accuracy:?????? 400uA, 4000uA ± (1.2%rdg+5dgt)
????????????? 40mA, 400mA ± (1.5%rdg+5dgt)
?10A ± (2.0%rdg+10dgt)
Input protection:??? 0.5A/250V fuse on 400mA range
10A/250V high energy fuses on 10A range
?
AC CURRENT (Auto Ranging)
Ranges:???? 400uA, 4000uA, 40mA, 400mA, 10A.
Resolution:???? 0.1uA
Frequency response: 50Hz to 400Hz
Accuracy:???? 400uA, 4000uA ±(1.8%rdg+5dgt)
40mA, 400mA ±(1.8%rdg+10dgt)
? 10A ± (2.5%rdg+10dgt)
Input protection:??? 0.5A/250V fuse on 400mA range
10A/250V high energy fuses on 10A range
?
RESISTANCE Ω (Auto Ranging)
Ranges:??? 400Ω, 4KΩ, 40KΩ, 400KΩ, 4MΩ, 40MΩ
Accuracy:? ± (1.2%rdg+10dgts) on 400Ω range
±(1.0%rdg+5dgts) on 4kΩ to 4MΩ ranges
???????????????????????????? ±(2.5%rdg+15dgts) on 40MΩ ranges
Open circuit voltage: 0.4VDC
Overload protections: 250VDC or RMS AC.
?
?
?
FERQUENCY (Auto Ranging)
Ranges:???????? 100Hz, 1 KHz, 100 KHz, 200 KHz
Resolution:??????????? 0.01Hz
Accuracy:???????????? ± (0.1%rdg+5dgts)
Sensitivity:???????????? 1V
Overload protection: 250VDC or RMS AC
?
CAPACITANCE (Auto Ranging)
Ranges:???????????????? 40nF, 400nF, 4uF, 40uF, 100uF.
Resolution:??????????? 10pF
Accuracy:????????????? ± (2.5%rdg+10dgts) on 40nF range
±(1.5%rdg+10dgts) on 400nF to 4uF ranges
±(2.5%rdg+15dgts) on 40uF to100uF ranges
Overload protection: 250V DC or RMS AC
?
DIODE TEST
Test current:????????? 0.6mA typical
Resolution:???????????? 1mV
Accuracy:????????????? ± (2.5%rdg+2gdts)
Open circuit voltage: 3.0Vdc typical
Overload protection: 250VDC or RMS AC.
?
AUDIBLE CONTINUITY
Open circuit voltage: